Mat Diffusion Analysis
Researchmat-diffusion-analysisMat Diffusion Analysis is an Agent Skill for research published in the learningmatter-mit/AtomisticSkills repository on GitHub: a SKILL.md instruction file an AI agent can load to do this task.
Calculate ionic diffusion coefficients and activation energy from MD trajectories using pymatgen.
How to use this skill
Bring this guide into your coding agent with a prompt tailored to the tool you use.
- Open your project in Codex.
- Copy and paste the prompt below.
- Review files and risks before approving any action.
Inspect the Agent Skill at https://github.com/learningmatter-mit/AtomisticSkills/blob/HEAD/.agents/skills/mat-diffusion-analysis/SKILL.md and all supporting files. Report provenance, permissions, scripts, dependencies, and security risks. Propose an exact installation into .agents/skills/mat-diffusion-analysis, but wait for my approval before writing files or running scripts.
Copying this prompt does not install or run the skill. Review third-party files before use.
Diffusion Analysis
Goal
To accurately calculate the ionic diffusivity ($D$) and activation energy ($E_a$) of specific atomic species in a material using Molecular Dynamics (MD) trajectories and the Arrhenius relation: $D(T) = D_0 \exp\left(-\frac{E_a}{k_B T}\right)$.
Instructions
-
MD Preparation: Run NVT or NPT MD simulations at multiple temperatures (typically 4-6 points between 600K and 1200K).
- Use the
run_mdtool from a relevant potential skill (e.g., mace or matgl). - Batch Processing: You can pass a directory or a list of CIF paths to
structure_datato run multiple MD simulations concurrently via the MCP tool. - Supercell Expansion: Ensure supercells are sufficiently large (> 10 Å in all dimensions). The
run_mdtool natively supports this via thesupercell_min_lengthargument (defaults to 10.0 Å) which performs orthogonal expansion automatically. - Optimization: Use the
diffusionmonitor (see mat-md-monitors) to automatically stop simulations once the transport properties have converged.
Note: If themace.run_md( structure_data=["candidates/A.cif", "candidates/B.cif"], temperature=600, supercell_min_length=10.0, monitor=True, monitor_type="diffusion", monitor_params={"specie": "Li", "threshold": 0.05, "check_interval_ps": 5.0} )diffusionmonitor triggers an early stop, it will automatically save thediffusion_{specie}.jsonandmsd_{specie}.pngdirectly into the trajectory output directory. You can skip Step 2 and proceed directly to Step 3 for any trajectories that converged early.
- Use the
-
Individual Diffusivity Analysis: For each temperature directory that did not hit the early stopping criteria, run the analysis script to extract the diffusivity and Mean Square Displacement (MSD).
# Env: base-agent python .agents/skills/mat-diffusion-analysis/scripts/analyze_diffusion.py \ results/md_600K/trajectory.traj \ --species Li \ --temperature 600 \ --ignore_ps 5.0 \ --output_dir results/md_600K--ignore_ps: Time to skip for equilibration. Default is 5.0 ps.- The script automatically detects the frame interval from the
.logfile if present.
-
Activation Energy Fitting: Once all individual results are generated, use the fitting script to combine data and perform a weighted Arrhenius fit.
# Env: base-agent python .agents/skills/mat-diffusion-analysis/scripts/calculate_activation_energy.py results/- The script looks for
md_*K/diffusion_results.jsonpatterns. - It performs error propagation to calculate uncertainty in $E_a$ and extrapolated room-temperature conductivity.
- The script looks for
Examples
- Superionic Conductor (LGPS): A complete workflow demonstration including supercell preparation, multi-temperature MD, and final Arrhenius plotting for $Li_{10}GeP_2S_{12}$ is available in the LGPS Example.
Constraints
- Trajectory Format: Trajectories MUST be in ASE
.trajformat. - Environments: All analysis scripts require the base-agent conda environment.
- Linearity: The diffusivity calculation assumes a linear diffusive regime. Always inspect the generated MSD plots to ensure linearity after the
ignore_psperiod. - Atom Count: To ensure statistical significance, the system should contain a sufficient number of mobile ions (> 20 recommended).
- Paths: Always use relative paths from the project root when executing scripts.
See Also
- mat-md-monitors: Real-time monitoring tools for MD simulations.
Author: Bowen Deng Contact: GitHub @learningmatter-mit